top of page

FIRE RESISTANT CABLES

Fire Performance Cables to maintain Circuit Integrity in Fire

ARMOURED FIRE RATED - FIRE SURVIVAL CABLE

Conductor 

Electrolyte Grade - Annealed Bare (99.9% Pure) 

Mica Tape 

1050°C Rated

Insulation

Zero Halogen and Low Smoke XLPE

Armour

Heavy Duty Round GI Steel Wire

Compliance

CE, LPCB, BS 7846 and BS 6387

Inner Sheath 

Zero-Halogen and Low Smoke Compound

Outer Sheath

Zero-Halogen and Low Smoke Compound

Armoured Fire Survival cables by NOTOFIRE® are specifically designed to provide circuit integrity in the event of a fire outbreak for 3 hours even when the temperature reaches 950° C. 

✔️LSZH fire-resistant insulation and sheath
✔️Offers continued functionality of critical systems in the event of a fire at a temperature of 950° C for up to 3 hours
✔️BASEC, EN, LPCB & UL Complied

UNARMOURED FIRE RATED - FIRE SURVIVAL CABLE

Conductor 

Electrolyte Grade - Annealed Bare (99.9% Pure) 

Mica Tape 

1050°C Rated

Insulation

Zero Halogen and Low Smoke XLPE

Compliance

CE, LPCB, BS 7846 and BS 6387

Shielding

Al-Mayer

Unarmoured Fire Survival cables by NOTOFIRE® are specifically designed to provide circuit integrity in the event of a fire outbreak for 3 hours even when the temperature reaches 950° C. 

✔️LSZH fire-resistant insulation and sheath
✔️Offers continued functionality of critical systems in the event of a fire at a temperature of 950° C for up to 3 hours
✔️BASEC, EN, LPCB & UL Complied

ARMOURED FIRE RESISTANT - FIRE ALARM CABLE

Conductor 

Electrolyte Grade - Annealed Bare (99.9% Pure) 

Insulation

Zero Halogen and Low Smoke XLPE

Compliance

CE, LPCB, BS 7846 and BS 6387

Zero-Halogen and Low Smoke Compound

Inner Sheath 

Armouring

Heavy Duty Round GI Stell Wire

NOTOFIRE® New Generation Armoured Fire Alarm Cables ensure maximum building safety and security by connecting fire alarm systems to lifelines. Liquid, temperature extremes, and various other environmental conditions do not affect NOTOFIRE® Fire Alarm Cables, making them suitable for extreme conditions.

✔️LSZH fire-resistant insulation and sheath
✔️Offers continued functionality of fire alarm system even in harsh conditions
✔️BASEC, EN, LPCB & UL Complied

UNARMOURED FIRE RESISTANT - FIRE ALARM CABLE

Conductor 

Electrolyte Grade - Annealed Bare (99.9% Pure) 

Mica Tape 

1050°C Rated

Insulation

Zero Halogen and Low Smoke XLPE

Compliance

CE, LPCB, BS 7846 and BS 6387

Shielding

Al Mayer

NOTOFIRE® New Generation Armoured Fire Alarm Cables ensure maximum building safety and security by connecting fire alarm systems to lifelines. Liquid, temperature extremes, and various other environmental conditions do not affect NOTOFIRE® Fire Alarm Cables, making them suitable for extreme conditions.

✔️LSZH fire-resistant insulation and sheath
✔️Offers continued functionality of fire alarm system even in harsh conditions
✔️BASEC, EN, LPCB & UL Complied

Get in Touch

Thanks for submitting!